de.sciss.synth.ugen

PulseDivider

final case class PulseDivider(rate: MaybeRate, trig: GE, div: GE = synth.this.GE.const(2), start: GE = synth.this.GE.const(0)) extends SingleOut with Product with Serializable

A UGen that decimates trigger by outputting one impulse each time a certain number of triggers at its input have been received.

trig

a trigger occurs when the signal changes from non-positive to positive.

div

decimation factor of the UGen. A value of 1 would cause an output trigger for each input trigger, whereas a value of 2 would cause an output trigger each time the internal counter has seen two input triggers.

start

value of the internal counter. For example, if div is 2 , then a start value of 0 (default) means that the first output trigger happens after two input triggers, a start value of 1 means that the first output trigger happens after just one input trigger. Negative values can increase the number of required input triggers for the first output trigger. For example, if start is -1 , the first output trigger happens after three input triggers.

See also

Stepper

PulseCount

Linear Supertypes
Serializable, Serializable, SingleOut, SomeOut, GE.Lazy, GE, UGenSource[UGenInLike], Expander[UGenInLike], Lazy, Product, Equals, AnyRef, Any
Ordering
  1. Alphabetic
  2. By inheritance
Inherited
  1. PulseDivider
  2. Serializable
  3. Serializable
  4. SingleOut
  5. SomeOut
  6. Lazy
  7. GE
  8. UGenSource
  9. Expander
  10. Lazy
  11. Product
  12. Equals
  13. AnyRef
  14. Any
  1. Hide All
  2. Show all
Learn more about member selection
Visibility
  1. Public
  2. All

Instance Constructors

  1. new PulseDivider(rate: MaybeRate, trig: GE, div: GE = synth.this.GE.const(2), start: GE = synth.this.GE.const(0))

    trig

    a trigger occurs when the signal changes from non-positive to positive.

    div

    decimation factor of the UGen. A value of 1 would cause an output trigger for each input trigger, whereas a value of 2 would cause an output trigger each time the internal counter has seen two input triggers.

    start

    value of the internal counter. For example, if div is 2 , then a start value of 0 (default) means that the first output trigger happens after two input triggers, a start value of 1 means that the first output trigger happens after just one input trigger. Negative values can increase the number of required input triggers for the first output trigger. For example, if start is -1 , the first output trigger happens after three input triggers.

Value Members

  1. final def !=(arg0: AnyRef): Boolean

    Definition Classes
    AnyRef
  2. final def !=(arg0: Any): Boolean

    Definition Classes
    Any
  3. final def ##(): Int

    Definition Classes
    AnyRef → Any
  4. final def ==(arg0: AnyRef): Boolean

    Definition Classes
    AnyRef
  5. final def ==(arg0: Any): Boolean

    Definition Classes
    Any
  6. final def asInstanceOf[T0]: T0

    Definition Classes
    Any
  7. def clone(): AnyRef

    Attributes
    protected[java.lang]
    Definition Classes
    AnyRef
    Annotations
    @throws( ... )
  8. val div: GE

    decimation factor of the UGen.

    decimation factor of the UGen. A value of 1 would cause an output trigger for each input trigger, whereas a value of 2 would cause an output trigger each time the internal counter has seen two input triggers.

  9. final def eq(arg0: AnyRef): Boolean

    Definition Classes
    AnyRef
  10. def finalize(): Unit

    Attributes
    protected[java.lang]
    Definition Classes
    AnyRef
    Annotations
    @throws( classOf[java.lang.Throwable] )
  11. final def getClass(): Class[_]

    Definition Classes
    AnyRef → Any
  12. lazy val hashCode: Int

    Definition Classes
    UGenSource → AnyRef → Any
  13. final def isInstanceOf[T0]: Boolean

    Definition Classes
    Any
  14. def makeUGens: UGenInLike

    Attributes
    protected
    Definition Classes
    PulseDivider → Expander
  15. final def name: String

    Definition Classes
    UGenSource
  16. final def ne(arg0: AnyRef): Boolean

    Definition Classes
    AnyRef
  17. final def notify(): Unit

    Definition Classes
    AnyRef
  18. final def notifyAll(): Unit

    Definition Classes
    AnyRef
  19. val rate: MaybeRate

    Definition Classes
    PulseDivider → GE
  20. val start: GE

    value of the internal counter.

    value of the internal counter. For example, if div is 2 , then a start value of 0 (default) means that the first output trigger happens after two input triggers, a start value of 1 means that the first output trigger happens after just one input trigger. Negative values can increase the number of required input triggers for the first output trigger. For example, if start is -1 , the first output trigger happens after three input triggers.

  21. final def synchronized[T0](arg0: ⇒ T0): T0

    Definition Classes
    AnyRef
  22. val trig: GE

    a trigger occurs when the signal changes from non-positive to positive.

  23. final def wait(): Unit

    Definition Classes
    AnyRef
    Annotations
    @throws( ... )
  24. final def wait(arg0: Long, arg1: Int): Unit

    Definition Classes
    AnyRef
    Annotations
    @throws( ... )
  25. final def wait(arg0: Long): Unit

    Definition Classes
    AnyRef
    Annotations
    @throws( ... )

Inherited from Serializable

Inherited from Serializable

Inherited from SingleOut

Inherited from SomeOut

Inherited from GE.Lazy

Inherited from GE

Inherited from UGenSource[UGenInLike]

Inherited from Expander[UGenInLike]

Inherited from Lazy

Inherited from Product

Inherited from Equals

Inherited from AnyRef

Inherited from Any

Ungrouped