public static final class DescriptorProtos.UninterpretedOption.Builder extends GeneratedMessage.Builder<DescriptorProtos.UninterpretedOption.Builder> implements DescriptorProtos.UninterpretedOptionOrBuilder
google.protobuf.UninterpretedOption
A message representing a option the parser does not recognize. This only appears in options protos created by the compiler::Parser class. DescriptorPool resolves these when building Descriptor objects. Therefore, options protos in descriptor objects (e.g. returned by Descriptor::options(), or produced by Descriptor::CopyTo()) will never have UninterpretedOptions in them.
Modifier and Type | Method and Description |
---|---|
DescriptorProtos.UninterpretedOption.Builder |
addAllName(Iterable<? extends DescriptorProtos.UninterpretedOption.NamePart> values)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
DescriptorProtos.UninterpretedOption.Builder |
addName(DescriptorProtos.UninterpretedOption.NamePart.Builder builderForValue)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
DescriptorProtos.UninterpretedOption.Builder |
addName(DescriptorProtos.UninterpretedOption.NamePart value)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
DescriptorProtos.UninterpretedOption.Builder |
addName(int index,
DescriptorProtos.UninterpretedOption.NamePart.Builder builderForValue)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
DescriptorProtos.UninterpretedOption.Builder |
addName(int index,
DescriptorProtos.UninterpretedOption.NamePart value)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
DescriptorProtos.UninterpretedOption.NamePart.Builder |
addNameBuilder()
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
DescriptorProtos.UninterpretedOption.NamePart.Builder |
addNameBuilder(int index)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
DescriptorProtos.UninterpretedOption |
build()
Constructs the message based on the state of the Builder.
|
DescriptorProtos.UninterpretedOption |
buildPartial()
Like
MessageLite.Builder.build() , but does not throw an exception if the message
is missing required fields. |
DescriptorProtos.UninterpretedOption.Builder |
clear()
Called by the initialization and clear code paths to allow subclasses to
reset any of their builtin fields back to the initial values.
|
DescriptorProtos.UninterpretedOption.Builder |
clearAggregateValue()
optional string aggregate_value = 8; |
DescriptorProtos.UninterpretedOption.Builder |
clearDoubleValue()
optional double double_value = 6; |
DescriptorProtos.UninterpretedOption.Builder |
clearIdentifierValue()
optional string identifier_value = 3; |
DescriptorProtos.UninterpretedOption.Builder |
clearName()
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
DescriptorProtos.UninterpretedOption.Builder |
clearNegativeIntValue()
optional int64 negative_int_value = 5; |
DescriptorProtos.UninterpretedOption.Builder |
clearPositiveIntValue()
optional uint64 positive_int_value = 4; |
DescriptorProtos.UninterpretedOption.Builder |
clearStringValue()
optional bytes string_value = 7; |
String |
getAggregateValue()
optional string aggregate_value = 8; |
ByteString |
getAggregateValueBytes()
optional string aggregate_value = 8; |
DescriptorProtos.UninterpretedOption |
getDefaultInstanceForType()
Get an instance of the type with no fields set.
|
static Descriptors.Descriptor |
getDescriptor() |
Descriptors.Descriptor |
getDescriptorForType()
Get the message's type's descriptor.
|
double |
getDoubleValue()
optional double double_value = 6; |
String |
getIdentifierValue()
optional string identifier_value = 3; |
ByteString |
getIdentifierValueBytes()
optional string identifier_value = 3; |
DescriptorProtos.UninterpretedOption.NamePart |
getName(int index)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
DescriptorProtos.UninterpretedOption.NamePart.Builder |
getNameBuilder(int index)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
List<DescriptorProtos.UninterpretedOption.NamePart.Builder> |
getNameBuilderList()
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
int |
getNameCount()
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
List<DescriptorProtos.UninterpretedOption.NamePart> |
getNameList()
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
DescriptorProtos.UninterpretedOption.NamePartOrBuilder |
getNameOrBuilder(int index)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
List<? extends DescriptorProtos.UninterpretedOption.NamePartOrBuilder> |
getNameOrBuilderList()
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
long |
getNegativeIntValue()
optional int64 negative_int_value = 5; |
long |
getPositiveIntValue()
optional uint64 positive_int_value = 4; |
ByteString |
getStringValue()
optional bytes string_value = 7; |
boolean |
hasAggregateValue()
optional string aggregate_value = 8; |
boolean |
hasDoubleValue()
optional double double_value = 6; |
boolean |
hasIdentifierValue()
optional string identifier_value = 3; |
boolean |
hasNegativeIntValue()
optional int64 negative_int_value = 5; |
boolean |
hasPositiveIntValue()
optional uint64 positive_int_value = 4; |
boolean |
hasStringValue()
optional bytes string_value = 7; |
protected GeneratedMessage.FieldAccessorTable |
internalGetFieldAccessorTable()
Get the FieldAccessorTable for this type.
|
boolean |
isInitialized()
Returns true if all required fields in the message and all embedded
messages are set, false otherwise.
|
DescriptorProtos.UninterpretedOption.Builder |
mergeFrom(CodedInputStream input,
ExtensionRegistryLite extensionRegistry)
Like
MessageLite.Builder.mergeFrom(CodedInputStream) , but also
parses extensions. |
DescriptorProtos.UninterpretedOption.Builder |
mergeFrom(DescriptorProtos.UninterpretedOption other) |
DescriptorProtos.UninterpretedOption.Builder |
mergeFrom(Message other)
Merge
other into the message being built. |
DescriptorProtos.UninterpretedOption.Builder |
removeName(int index)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
DescriptorProtos.UninterpretedOption.Builder |
setAggregateValue(String value)
optional string aggregate_value = 8; |
DescriptorProtos.UninterpretedOption.Builder |
setAggregateValueBytes(ByteString value)
optional string aggregate_value = 8; |
DescriptorProtos.UninterpretedOption.Builder |
setDoubleValue(double value)
optional double double_value = 6; |
DescriptorProtos.UninterpretedOption.Builder |
setIdentifierValue(String value)
optional string identifier_value = 3; |
DescriptorProtos.UninterpretedOption.Builder |
setIdentifierValueBytes(ByteString value)
optional string identifier_value = 3; |
DescriptorProtos.UninterpretedOption.Builder |
setName(int index,
DescriptorProtos.UninterpretedOption.NamePart.Builder builderForValue)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
DescriptorProtos.UninterpretedOption.Builder |
setName(int index,
DescriptorProtos.UninterpretedOption.NamePart value)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2; |
DescriptorProtos.UninterpretedOption.Builder |
setNegativeIntValue(long value)
optional int64 negative_int_value = 5; |
DescriptorProtos.UninterpretedOption.Builder |
setPositiveIntValue(long value)
optional uint64 positive_int_value = 4; |
DescriptorProtos.UninterpretedOption.Builder |
setStringValue(ByteString value)
optional bytes string_value = 7; |
addRepeatedField, clearField, clearOneof, clone, getAllFields, getField, getFieldBuilder, getOneofFieldDescriptor, getParentForChildren, getRepeatedField, getRepeatedFieldBuilder, getRepeatedFieldCount, getUnknownFields, hasField, hasOneof, internalGetMapField, internalGetMutableMapField, isClean, markClean, mergeUnknownFields, newBuilderForField, onBuilt, onChanged, parseUnknownField, setField, setRepeatedField, setUnknownFields
findInitializationErrors, getInitializationErrorString, mergeDelimitedFrom, mergeDelimitedFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, mergeFrom, newUninitializedMessageException, toString
addAll, newUninitializedMessageException
equals, finalize, getClass, hashCode, notify, notifyAll, wait, wait, wait
findInitializationErrors, getAllFields, getField, getInitializationErrorString, getOneofFieldDescriptor, getRepeatedField, getRepeatedFieldCount, getUnknownFields, hasField, hasOneof
public static final Descriptors.Descriptor getDescriptor()
protected GeneratedMessage.FieldAccessorTable internalGetFieldAccessorTable()
GeneratedMessage.Builder
internalGetFieldAccessorTable
in class GeneratedMessage.Builder<DescriptorProtos.UninterpretedOption.Builder>
public DescriptorProtos.UninterpretedOption.Builder clear()
GeneratedMessage.Builder
clear
in interface Message.Builder
clear
in interface MessageLite.Builder
clear
in class GeneratedMessage.Builder<DescriptorProtos.UninterpretedOption.Builder>
public Descriptors.Descriptor getDescriptorForType()
Message.Builder
MessageOrBuilder.getDescriptorForType()
.getDescriptorForType
in interface Message.Builder
getDescriptorForType
in interface MessageOrBuilder
getDescriptorForType
in class GeneratedMessage.Builder<DescriptorProtos.UninterpretedOption.Builder>
public DescriptorProtos.UninterpretedOption getDefaultInstanceForType()
MessageLiteOrBuilder
getDefaultInstance()
method of generated message classes in that
this method is an abstract method of the MessageLite
interface
whereas getDefaultInstance()
is a static method of a specific
class. They return the same thing.getDefaultInstanceForType
in interface MessageLiteOrBuilder
getDefaultInstanceForType
in interface MessageOrBuilder
public DescriptorProtos.UninterpretedOption build()
MessageLite.Builder
build
in interface Message.Builder
build
in interface MessageLite.Builder
public DescriptorProtos.UninterpretedOption buildPartial()
MessageLite.Builder
MessageLite.Builder.build()
, but does not throw an exception if the message
is missing required fields. Instead, a partial message is returned.
Subsequent changes to the Builder will not affect the returned message.buildPartial
in interface Message.Builder
buildPartial
in interface MessageLite.Builder
public DescriptorProtos.UninterpretedOption.Builder mergeFrom(Message other)
Message.Builder
other
into the message being built. other
must
have the exact same type as this
(i.e.
getDescriptorForType() == other.getDescriptorForType()
).
Merging occurs as follows. For each field:other
,
then other
's value overwrites the value in this message.other
,
it is merged into the corresponding sub-message of this message
using the same merging rules.other
are concatenated
with the elements in this message.
This is equivalent to the Message::MergeFrom
method in C++.mergeFrom
in interface Message.Builder
mergeFrom
in class AbstractMessage.Builder<DescriptorProtos.UninterpretedOption.Builder>
public DescriptorProtos.UninterpretedOption.Builder mergeFrom(DescriptorProtos.UninterpretedOption other)
public final boolean isInitialized()
MessageLiteOrBuilder
isInitialized
in interface MessageLiteOrBuilder
isInitialized
in class GeneratedMessage.Builder<DescriptorProtos.UninterpretedOption.Builder>
public DescriptorProtos.UninterpretedOption.Builder mergeFrom(CodedInputStream input, ExtensionRegistryLite extensionRegistry) throws IOException
MessageLite.Builder
MessageLite.Builder.mergeFrom(CodedInputStream)
, but also
parses extensions. The extensions that you want to be able to parse
must be registered in extensionRegistry
. Extensions not in
the registry will be treated as unknown fields.mergeFrom
in interface Message.Builder
mergeFrom
in interface MessageLite.Builder
mergeFrom
in class AbstractMessage.Builder<DescriptorProtos.UninterpretedOption.Builder>
IOException
public List<DescriptorProtos.UninterpretedOption.NamePart> getNameList()
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
getNameList
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public int getNameCount()
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
getNameCount
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public DescriptorProtos.UninterpretedOption.NamePart getName(int index)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
getName
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public DescriptorProtos.UninterpretedOption.Builder setName(int index, DescriptorProtos.UninterpretedOption.NamePart value)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
public DescriptorProtos.UninterpretedOption.Builder setName(int index, DescriptorProtos.UninterpretedOption.NamePart.Builder builderForValue)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
public DescriptorProtos.UninterpretedOption.Builder addName(DescriptorProtos.UninterpretedOption.NamePart value)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
public DescriptorProtos.UninterpretedOption.Builder addName(int index, DescriptorProtos.UninterpretedOption.NamePart value)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
public DescriptorProtos.UninterpretedOption.Builder addName(DescriptorProtos.UninterpretedOption.NamePart.Builder builderForValue)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
public DescriptorProtos.UninterpretedOption.Builder addName(int index, DescriptorProtos.UninterpretedOption.NamePart.Builder builderForValue)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
public DescriptorProtos.UninterpretedOption.Builder addAllName(Iterable<? extends DescriptorProtos.UninterpretedOption.NamePart> values)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
public DescriptorProtos.UninterpretedOption.Builder clearName()
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
public DescriptorProtos.UninterpretedOption.Builder removeName(int index)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
public DescriptorProtos.UninterpretedOption.NamePart.Builder getNameBuilder(int index)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
public DescriptorProtos.UninterpretedOption.NamePartOrBuilder getNameOrBuilder(int index)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
getNameOrBuilder
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public List<? extends DescriptorProtos.UninterpretedOption.NamePartOrBuilder> getNameOrBuilderList()
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
getNameOrBuilderList
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public DescriptorProtos.UninterpretedOption.NamePart.Builder addNameBuilder()
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
public DescriptorProtos.UninterpretedOption.NamePart.Builder addNameBuilder(int index)
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
public List<DescriptorProtos.UninterpretedOption.NamePart.Builder> getNameBuilderList()
repeated .google.protobuf.UninterpretedOption.NamePart name = 2;
public boolean hasIdentifierValue()
optional string identifier_value = 3;
The value of the uninterpreted option, in whatever type the tokenizer identified it as during parsing. Exactly one of these should be set.
hasIdentifierValue
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public String getIdentifierValue()
optional string identifier_value = 3;
The value of the uninterpreted option, in whatever type the tokenizer identified it as during parsing. Exactly one of these should be set.
getIdentifierValue
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public ByteString getIdentifierValueBytes()
optional string identifier_value = 3;
The value of the uninterpreted option, in whatever type the tokenizer identified it as during parsing. Exactly one of these should be set.
getIdentifierValueBytes
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public DescriptorProtos.UninterpretedOption.Builder setIdentifierValue(String value)
optional string identifier_value = 3;
The value of the uninterpreted option, in whatever type the tokenizer identified it as during parsing. Exactly one of these should be set.
public DescriptorProtos.UninterpretedOption.Builder clearIdentifierValue()
optional string identifier_value = 3;
The value of the uninterpreted option, in whatever type the tokenizer identified it as during parsing. Exactly one of these should be set.
public DescriptorProtos.UninterpretedOption.Builder setIdentifierValueBytes(ByteString value)
optional string identifier_value = 3;
The value of the uninterpreted option, in whatever type the tokenizer identified it as during parsing. Exactly one of these should be set.
public boolean hasPositiveIntValue()
optional uint64 positive_int_value = 4;
hasPositiveIntValue
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public long getPositiveIntValue()
optional uint64 positive_int_value = 4;
getPositiveIntValue
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public DescriptorProtos.UninterpretedOption.Builder setPositiveIntValue(long value)
optional uint64 positive_int_value = 4;
public DescriptorProtos.UninterpretedOption.Builder clearPositiveIntValue()
optional uint64 positive_int_value = 4;
public boolean hasNegativeIntValue()
optional int64 negative_int_value = 5;
hasNegativeIntValue
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public long getNegativeIntValue()
optional int64 negative_int_value = 5;
getNegativeIntValue
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public DescriptorProtos.UninterpretedOption.Builder setNegativeIntValue(long value)
optional int64 negative_int_value = 5;
public DescriptorProtos.UninterpretedOption.Builder clearNegativeIntValue()
optional int64 negative_int_value = 5;
public boolean hasDoubleValue()
optional double double_value = 6;
hasDoubleValue
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public double getDoubleValue()
optional double double_value = 6;
getDoubleValue
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public DescriptorProtos.UninterpretedOption.Builder setDoubleValue(double value)
optional double double_value = 6;
public DescriptorProtos.UninterpretedOption.Builder clearDoubleValue()
optional double double_value = 6;
public boolean hasStringValue()
optional bytes string_value = 7;
hasStringValue
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public ByteString getStringValue()
optional bytes string_value = 7;
getStringValue
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public DescriptorProtos.UninterpretedOption.Builder setStringValue(ByteString value)
optional bytes string_value = 7;
public DescriptorProtos.UninterpretedOption.Builder clearStringValue()
optional bytes string_value = 7;
public boolean hasAggregateValue()
optional string aggregate_value = 8;
hasAggregateValue
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public String getAggregateValue()
optional string aggregate_value = 8;
getAggregateValue
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public ByteString getAggregateValueBytes()
optional string aggregate_value = 8;
getAggregateValueBytes
in interface DescriptorProtos.UninterpretedOptionOrBuilder
public DescriptorProtos.UninterpretedOption.Builder setAggregateValue(String value)
optional string aggregate_value = 8;
public DescriptorProtos.UninterpretedOption.Builder clearAggregateValue()
optional string aggregate_value = 8;
public DescriptorProtos.UninterpretedOption.Builder setAggregateValueBytes(ByteString value)
optional string aggregate_value = 8;
Copyright © 2008–2015 Google. All rights reserved.