Package eu.entsoe.wgedi.codelists
Enum Class StandardAnalogTypeList
- All Implemented Interfaces:
Serializable
,Comparable<StandardAnalogTypeList>
,Constable
Java class for StandardAnalogTypeList.
The following schema fragment specifies the expected content contained within this class.
<simpleType name="StandardAnalogTypeList"> <restriction base="{http://www.w3.org/2001/XMLSchema}NMTOKEN"> <enumeration value="A01"/> <enumeration value="A02"/> <enumeration value="A03"/> <enumeration value="A04"/> <enumeration value="A05"/> <enumeration value="A06"/> <enumeration value="A07"/> <enumeration value="A08"/> <enumeration value="A09"/> <enumeration value="A10"/> <enumeration value="A11"/> <enumeration value="A12"/> <enumeration value="A13"/> <enumeration value="A14"/> <enumeration value="A15"/> <enumeration value="A16"/> <enumeration value="A17"/> <enumeration value="A18"/> <enumeration value="A19"/> <enumeration value="A20"/> <enumeration value="A21"/> <enumeration value="A22"/> </restriction> </simpleType>
-
Nested Class Summary
Nested classes/interfaces inherited from class java.lang.Enum
Enum.EnumDesc<E extends Enum<E>>
-
Enum Constant Summary
Enum ConstantDescription<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Flow</Title><Definition>This is the computed flow for the monitored element in the constraint situation ("N situation", "N-1 situation" ...) after the capacity calculation.<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Permanent admissible transmission limit (PATL)</Title><Definition>The permanent load of transmission system elements which is allowed for an unlimited period and which does not cause physical damage to the transmission system elements as long as the defined threshold is respected.</Definition></CodeDescription><?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Flow reliability margin</Title><Definition>This is the flow reliability margin for a given critical network element.<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Spanning margin value</Title><Definition>This is the margin that is taken into account when spanning (fall-back process) is applied.<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Long term allocation margin</Title><Definition>This is the amount of MW that is added to the capacity of the critical network element in order to automatically include the long term allocation domain into the flow based domain.</Definition></CodeDescription><?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Final adjustment margin value</Title><Definition>This is the margin that is manually added or subtracted to the capacity of the critical network element.<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Transitory admissible transmission limit (TATL)</Title><Definition>The temporary overload of transmission system elements which is allowed for a limited period and which does not cause physical damage to the transmission system elements as long as the defined duration and thresholds are respected.</Definition></CodeDescription><?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Long admissible flow</Title><Definition>This is the value, expressed in A or MW, that the overload flow in a network element shall not exceed for a duration no longer than the long duration.<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Negative Final adjustment margin value</Title><Definition>This is the margin that is manually added to the capacity of the critical network element in order to simulate the effect of an additional margin due to complex remedial actions (RA) which cannot be modeled and so calculated in the flow based parameter calculation.</Definition></CodeDescription><?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Minimum voltage level</Title><Definition>This is the minimum voltage that can be supported by a network element without involving a risk for the security of supply.</Definition></CodeDescription><?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Maximum voltage level</Title><Definition>This is the maximum voltage that can be supported by a network element without involving a risk for the security of supply.</Definition></CodeDescription><?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>TATL after automatic RA</Title><Definition>The Transitory admissible transmission limit (TATL) which is allowed after an automatic Remedial Action (RA) has been applied.</Definition></CodeDescription><?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>TATL after curative RA</Title><Definition>The Transitory admissible transmission limit (TATL) which is allowed after a curative Remedial Action (RA) has been applied.</Definition></CodeDescription><?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Computed Voltage</Title><Definition>This is the computed voltage for a given monitored element.</Definition></CodeDescription><?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Zero-Balance flow</Title><Definition>This is the amount of power affected by a contingency that reflects a situation with a scheduled exchange of zero.</Definition></CodeDescription><?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Available margin after remedial actions</Title><Definition>This is the available flow margin adjusted for the consideration of remedial actions in capacity calculation.</Definition></CodeDescription><?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Loss Factor</Title><Definition>This is the loss factor for an asset.</Definition></CodeDescription><?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Adjustment for minimum RAM</Title><Definition>This is the adjustment applied to the capacity of a branch to have a minimum RAM (Remaining Available Margin) available for commercial exchanges.</Definition></CodeDescription><?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Tap changer</Title><Definition>The position of a Tap changer.</Definition></CodeDescription><?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Regulator mode</Title><Definition>A measurement type indicating the control mode of a regulator, i.e.<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Regulator set-point</Title><Definition>The set-point of a regulator.<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Reference Flow</Title><Definition>This is the amount of power affected by a contingency that reflects a situation with scheduled exchanges from a reference situation.</Definition></CodeDescription> -
Method Summary
Modifier and TypeMethodDescriptionstatic StandardAnalogTypeList
value()
static StandardAnalogTypeList
Returns the enum constant of this class with the specified name.static StandardAnalogTypeList[]
values()
Returns an array containing the constants of this enum class, in the order they are declared.
-
Enum Constant Details
-
A_01
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Flow</Title><Definition>This is the computed flow for the monitored element in the constraint situation ("N situation", "N-1 situation" ...) after the capacity calculation. The flow is expressed in A, %, or MW.</Definition></CodeDescription>
-
A_02
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Permanent admissible transmission limit (PATL)</Title><Definition>The permanent load of transmission system elements which is allowed for an unlimited period and which does not cause physical damage to the transmission system elements as long as the defined threshold is respected.</Definition></CodeDescription>
-
A_03
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Flow reliability margin</Title><Definition>This is the flow reliability margin for a given critical network element. The amount of MW or A that is reserved for this critical network element and shall not be used for the computed outage situation, in order to secure the power network.</Definition></CodeDescription>
-
A_04
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Spanning margin value</Title><Definition>This is the margin that is taken into account when spanning (fall-back process) is applied. Spanning marginal value is an historical based parameter which specifies the amount of MW that reduces the RAM when spanning is applied.</Definition></CodeDescription>
-
A_05
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Long term allocation margin</Title><Definition>This is the amount of MW that is added to the capacity of the critical network element in order to automatically include the long term allocation domain into the flow based domain.</Definition></CodeDescription>
-
A_06
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Final adjustment margin value</Title><Definition>This is the margin that is manually added or subtracted to the capacity of the critical network element. A negative value for final adjustment value simulates the effect of an additional margin due to complex remedial actions (RA) which cannot be modeled and so calculated in the flow based parameter calculation. A positive value for FAV as a consequence of the verification phase of the flow based domain, leading to the need to reduce the margin on one or more CBs for system security reasons.</Definition></CodeDescription>
-
A_07
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Transitory admissible transmission limit (TATL)</Title><Definition>The temporary overload of transmission system elements which is allowed for a limited period and which does not cause physical damage to the transmission system elements as long as the defined duration and thresholds are respected.</Definition></CodeDescription>
-
A_08
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Long admissible flow</Title><Definition>This is the value, expressed in A or MW, that the overload flow in a network element shall not exceed for a duration no longer than the long duration. The long duration value depends on the TSO network operating rules.</Definition></CodeDescription>
-
A_09
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Negative Final adjustment margin value</Title><Definition>This is the margin that is manually added to the capacity of the critical network element in order to simulate the effect of an additional margin due to complex remedial actions (RA) which cannot be modeled and so calculated in the flow based parameter calculation.</Definition></CodeDescription>
-
A_10
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Minimum voltage level</Title><Definition>This is the minimum voltage that can be supported by a network element without involving a risk for the security of supply.</Definition></CodeDescription>
-
A_11
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Maximum voltage level</Title><Definition>This is the maximum voltage that can be supported by a network element without involving a risk for the security of supply.</Definition></CodeDescription>
-
A_12
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>TATL after automatic RA</Title><Definition>The Transitory admissible transmission limit (TATL) which is allowed after an automatic Remedial Action (RA) has been applied.</Definition></CodeDescription>
-
A_13
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>TATL after curative RA</Title><Definition>The Transitory admissible transmission limit (TATL) which is allowed after a curative Remedial Action (RA) has been applied.</Definition></CodeDescription>
-
A_14
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Computed Voltage</Title><Definition>This is the computed voltage for a given monitored element.</Definition></CodeDescription>
-
A_15
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Zero-Balance flow</Title><Definition>This is the amount of power affected by a contingency that reflects a situation with a scheduled exchange of zero.</Definition></CodeDescription>
-
A_16
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Available margin after remedial actions</Title><Definition>This is the available flow margin adjusted for the consideration of remedial actions in capacity calculation.</Definition></CodeDescription>
-
A_17
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Loss Factor</Title><Definition>This is the loss factor for an asset.</Definition></CodeDescription>
-
A_18
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Adjustment for minimum RAM</Title><Definition>This is the adjustment applied to the capacity of a branch to have a minimum RAM (Remaining Available Margin) available for commercial exchanges.</Definition></CodeDescription>
-
A_19
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Tap changer</Title><Definition>The position of a Tap changer.</Definition></CodeDescription>
-
A_20
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Regulator mode</Title><Definition>A measurement type indicating the control mode of a regulator, i.e. from voltage regulation to fixed MVAR regulation.</Definition></CodeDescription>
-
A_21
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Regulator set-point</Title><Definition>The set-point of a regulator. A regulator can be a tap changer, a synchronous machine, a SVC or a shunt.</Definition></CodeDescription>
-
A_22
<?xml version="1.0" encoding="UTF-8"?><CodeDescription xmlns:ecl="urn:entsoe.eu:wgedi:codelists" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><Title>Reference Flow</Title><Definition>This is the amount of power affected by a contingency that reflects a situation with scheduled exchanges from a reference situation.</Definition></CodeDescription>
-
-
Method Details
-
values
Returns an array containing the constants of this enum class, in the order they are declared.- Returns:
- an array containing the constants of this enum class, in the order they are declared
-
valueOf
Returns the enum constant of this class with the specified name. The string must match exactly an identifier used to declare an enum constant in this class. (Extraneous whitespace characters are not permitted.)- Parameters:
name
- the name of the enum constant to be returned.- Returns:
- the enum constant with the specified name
- Throws:
IllegalArgumentException
- if this enum class has no constant with the specified nameNullPointerException
- if the argument is null
-
value
-
fromValue
-